HOUSTON
6550 Bingle Rd.
Houston, TX 77092
(713) 462-5470 - PH
(713) 462-4853 - FAX
ROUND ROCK
16713 Central Commerce Dr.
Round Rock, TX 78664
(512) 252-7737 - PH
(512) 252-7757 - FAX
 
/images/store/55/Concrete_Pour_pict.jpg/images/store/55/Concrete_Pour_Trowel_3.jpg/images/store/55/Contractor_W-Plans_6.jpg
/images/store/55/CraneSunset.jpg/images/store/55/Drywall_App_4.jpg/images/store/55/Grading_5.jpg
/images/store/55/Industrial_pict.jpg/images/store/55/Masonry_App_7.jpg/images/store/55/Masonry_pict.jpg
/images/store/55/Plywood_pict.jpg/images/store/55/Tilt-Up_Workers_App_2.jpg/images/store/55/Tilt-Up_Workers_App_4.jpg
 

Search:

HI 750 - Skid Mounted Indirect Air Heaters - mobile

HI 750

Wacker Neuson

Robust and versatile for multiple heating applications

The most versatile, robust, indirect fired air heaters, the HI 750 produce clean, moisture free air for various heating and drying applications. Easy set-up and simple operation make these units extremely user friendly. The HI 750 can handle heating and drying applications with 750,000 Btu's/hr at over 83% efficiency. This air heater is designed to operate on diesel, natural gas or propane for maximum job site convenience and is able to fit through 36" door opening. Machines are CSA certified.

(click image to enlarge)
Quick Overview
  • Feature:
  • Unique Recircul-Air design allows adjustable recirculation of warm inside air, while pressurizing with frees air, resulting in fuel savings and even temperatures.
  • Industry leading for heat delivery in its class, boasting up to 6,450 cubic feet per minute. New adjustable air damper provides flexibility in CFM delivery and heat rise up to 140 degrees F.
  • Durable heat exchanger and combustion chamber, made from 409 stainless steel for longer life, comes standard with extended warranty.
  • Static pressure gauge gives user visibility to maximize heat delivery and avoid heated output air restrictions
  • Optional "plug and play" burner kit can easily convert machine from diesel to natural gas/propane. The extra large burner compartment is ideal for simple burner conversion or service access.
Interested in this item or want more information?
Call Mon. through Fri. 7:00 AM - 5:00 PM CST
Phone: (713) 462-5470
Email: Sales@KrisCon.com

Can't find what you want? Give us a call and we can help you find it.
Details
Technical specifications:

Indirect Air Heaters - Mobile

 HI 750 DHI 750 G
Dimensions
L x W x H Overall in139 x 47 x 77139 x 46.8 x 65.5
L x W x H Shipping in151 x 50 x 84151 x 50 x 76.5
Weight without Fuel lb2,5672,550
Operating weight with Fuel lb3,4002,550
Shipping weight with packaging lb2,8912,874
Operating data
Diameter Flue in88
Diameter Air Outlets qty (2 or 3) in2020
Diameter Air Outlets (qty 2) in1616
Diameter Air Outlets (qty 4) in1212
Diameter Air Returns (qty 2) in2020
Heating power Heat Input BTU/h750,000750,000
Capacity Sizing Air Heat ft³1,037,5001,037,500
Capacity Drying Size ft³369,214369,217
Air flow CFM6,4476,447
Heat efficiency %8383
Operating temperature Air Temperature Rise ° F108108
Static Pressure W.C. (inch)22
Length Max Duct - 2 x 20in Supply ft200200
Length Max Duct - 2 x 16in Supply ft100100
Length Max Duct - 4 x 12in Supply ft100100
Length Max Duct - 2 x 20in Return ft100100
Runtime h19.30
Electrical system
Frequency Hz6060
Current A15/3015/30
Voltage V115/230115/230
Engine / Motor
Fuel type DieselNG/LP
Tank capacity Diesel US gal102.40
Fuel consumption Diesel/LP US gal/h5.328.2
Fuel consumption (natural gas) Natural Gas ft³/h0750